Home page

Welcome, Guest | English | USD | Sign In
Showing 71 - 80 of 465 Results
 
Page: 1 2 3 4 5 6 7 8 9 10 > >> 
Results Per Page: 10 | 25 | 50
Hide Thumbnail
Item Number Manufacturer
Description
TXP-T40 Sensor, Hydrogen Sulfide (H2S) 0-50 PPM, Electrochemical 86-3130-1800-00 Macurco Gas Detection
TXP-T40 Sensor, Hydrogen Sulfide (H2S) 0-50 PPM, Electrochemical
TXP-T40 Sensor, Hydrogen Sulfide (H2S) 0-100 PPM, Electrochemical 86-3130-1900-00 Macurco Gas Detection
TXP-T40 Sensor, Hydrogen Sulfide (H2S) 0-100 PPM, Electrochemical
TXP-T40 Sensor, Hydrogen Sulfide (H2S) 0-200 PPM, Electrochemical 86-3130-2000-00 Macurco Gas Detection
TXP-T40 Sensor, Hydrogen Sulfide (H2S) 0-200 PPM, Electrochemical
TXP-T40 Sensor, Hydrogen Sulfide (H2S) 0-500 PPM, Electrochemical 86-3130-2200-00 Macurco Gas Detection
TXP-T40 Sensor, Hydrogen Sulfide (H2S) 0-500 PPM, Electrochemical
TXP-T40 Sensor, Nitrogen Dioxide (NO2) 0-20 PPM, Electrochemical 86-3134-1500-00 Macurco Gas Detection
TXP-T40 Sensor, Nitrogen Dioxide (NO2) 0-20 PPM, Electrochemical
TXP-T40 Sensor, Sulfur Dioxide (SO2) 0-20 PPM, Electrochemical 86-3140-1500-00 Macurco Gas Detection
TXP-T40 Sensor, Sulfur Dioxide (SO2) 0-20 PPM, Electrochemical
Calibration Adapter (All TXP Transmitters w/S.S. sensor housing) 88-C50I-0000-00 Macurco Gas Detection
Calibration Adapter (All TXP Transmitters w/S.S. sensor housing)
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 24V DC. C1, D2. 90-1110-1000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 24V DC. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D2. 90-1110-2000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 24V DC. C1, D2. 90-1110-3000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 24V DC. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 24V DC. C1, D2. 90-1110-4000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 24V DC. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2. 90-1112-1000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location. 90-1112-1003-05 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2. 90-1112-1007-25 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2. 90-1112-2000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location. 90-1112-2003-05 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2. 90-1112-2007-25 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2. 90-1112-3000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location. 90-1112-3003-05 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2. 90-1112-3007-25 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2. 90-1112-4000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location. 90-1112-4003-05 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2. 90-1112-4007-25 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X PY ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 24V DC. C1, D2. 90-1210-1000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 24V DC. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D2. 90-1210-2000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 24V DC. C1, D2. 90-1210-3000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 24V DC. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 24V DC. C1, D2. 90-1210-4000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 24V DC. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2. 90-1212-1000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location. 90-1212-1003-05 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2. 90-1212-1007-25 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2. 90-1212-2000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location. 90-1212-2003-05 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2. 90-1212-2007-25 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2. 90-1212-3000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location. 90-1212-3003-05 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2. 90-1212-3007-25 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) bridge sensor (Catalytic bead / IR) inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2. 90-1212-4000-20 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location. 90-1212-4003-05 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. Non-Hazardous Location.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2. 90-1212-4007-25 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 4X S.S. ext. enclosure, (2) electrochemical sensor inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply, (1) Amber Strobe, (1) Red Strobe, 100 dB Piezo. C1, D2.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D1. 90-1410-1000-10 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D1.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D1. 90-1410-2000-10 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D1.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D1. 90-1410-3000-10 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D1.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D1. 90-1410-4000-10 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 24V DC. C1, D1.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W external NEMA 7 power supply. C1, D1. 90-1414-1000-10 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W external NEMA 7 power supply. C1, D1.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W external NEMA 7 power supply. C1, D1. 90-1414-2000-10 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W external NEMA 7 power supply. C1, D1.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W external NEMA 7 power supply. C1, D1. 90-1414-3000-10 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W external NEMA 7 power supply. C1, D1.
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W external NEMA 7 power supply. C1, D1. 90-1414-4000-10 Macurco Gas Detection
TXP-C20 dual channel controller, (3) alarm levels per channel, NEMA 7 explosion proof enclosure, (1) bridge (Catalytic bead / IR) & (1) electrochemcial sensor input, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W external NEMA 7 power supply. C1, D1.
TXP-C40 four channel controller, (3) alarm levels per channel, NEMA 4X Poly ext. enclosure, (4) 4 - 20 mA inputs, (2) configurable common Relays, 24V DC. C1, D2. 90-2120-5000-20 Macurco Gas Detection
TXP-C40 four channel controller, (3) alarm levels per channel, NEMA 4X Poly ext. enclosure, (4) 4 - 20 mA inputs, (2) configurable common Relays, 24V DC. C1, D2.
TXP-C40 four channel controller, (3) alarm levels per channel, NEMA 4X Poly ext. enclosure, (4) bridge (Catalytic bead / IR) or (2) bridge and (2) electrochemcial sensor inputs, (2) configurable common Relays, 24V DC. C1, D2. 90-2120-6000-20 Macurco Gas Detection
TXP-C40 four channel controller, (3) alarm levels per channel, NEMA 4X Poly ext. enclosure, (4) bridge (Catalytic bead / IR) or (2) bridge and (2) electrochemcial sensor inputs, (2) configurable common Relays, 24V DC. C1, D2.
TXP-C40 four channel controller, (3) alarm levels per channel, NEMA 4X Poly ext. enclosure, (4) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2. 90-2122-5000-20 Macurco Gas Detection
TXP-C40 four channel controller, (3) alarm levels per channel, NEMA 4X Poly ext. enclosure, (4) 4 - 20 mA inputs, (2) configurable common Relays, 100-240V AC / 10-30VDC w/50W power supply. C1, D2.
Showing 71 - 80 of 465 Results
 
Page: 1 2 3 4 5 6 7 8 9 10 > >>