Item Number |
Manufacturer |
|
Description |
 |
2700569 |
Phoenix Contact |
|
PSR-MC40-3NO-1DO-24DC-SC |
 |
2700467 |
Phoenix Contact |
|
PSR-MC20-3NO-1DO-24DC-SP: Safety relay for emergency stop/safety doors up to SILCL 1 Cat. 1 PL c depending on the application up to SILCL 3 Cat. 4 PL e 1-channel operation automatic/manual start 3 enabling current paths U = 24 V DC plug-in spring-cage term |
 |
2700498 |
Phoenix Contact |
|
PSR-MC30-2NO-1DO-24DC-SC: Safety relay for emergency stop and safety doors up to SILCL 3 Cat. 4 PL e 1 or 2-channel operation automatic or manual monitored start cross-circuit detection 2 enabling current paths U = 24 V DC plug-in screw terminal block |
 |
2700499 |
Phoenix Contact |
|
PSR-MC30-2NO-1DO-24DC-SP: Safety relay for emergency stop and safety doors up to SIL 3 SILCL 3 Cat. 4 PL e 1 or 2-channel operation automatic or manual monitored start cross-circuit detection 2 enabling current paths U = 24 V DC plug-in spring-cage termina |
 |
2700524 |
Phoenix Contact |
|
PSR-MC32-3NO-1NC-24-230UC-SC: Safety relay for emergency stop safety doors and light grids up to SILCL 3 Cat. 4 PL e 1 or 2-channel operation automatic or manual monitored start 3 enabling current paths 1 signaling current path U = 24 ... 230 V AC/DC plug- |
 |
2700525 |
Phoenix Contact |
|
PSR-MC32-3NO-1NC-24-230UC-SP: Safety relay for emergency stop safety doors and light grids up to SILCL 3 Cat. 4 PL e 1 or 2-channel operation automatic or manual monitored start 3 enabling current paths 1 signaling current path U = 24 ... 230 V AC/DC plug- |
 |
2700548 |
Phoenix Contact |
|
PSR-MC34-3NO-1DO-24DC-SP: Safety relay for emergency stop and safety doors up to SILCL 3 Cat. 4 PL e 1 or 2-channel operation automatic or manual monitored start cross-circuit detection 3 enabling current paths U = 24 V DC plug-in spring-cage terminal bloc |
 |
2700553 |
Phoenix Contact |
|
PSR-MC50-3NO-1DO-24DC-SC: Safety relay for monitoring non-equivalent signal generators up to SILCL 3 Cat. 4 PL e 2-channel non-equivalent operation automatic or manual monitored start 3 enabling current paths U = 24 V DC plug-in screw terminal block |
 |
2700564 |
Phoenix Contact |
|
PSR-MC50-3NO-1DO-24DC-SP: Safety relay for monitoring non-equivalent signal generators up to SILCL 3 Cat. 4 PL e 2-channel non-equivalent operation automatic or manual monitored start 3 enabling current paths U = 24 V DC plug-in spring-cage terminal block |
 |
2700570 |
Phoenix Contact |
|
PSR-MC40-3NO-1DO-24DC-SP: Safety relay for emergency stop safety doors and light grids up to SILCL 3 Cat. 4 PL e 1 or 2-channel operation automatic or manual monitored start 3 enabling current paths U = 24 V DC plug-in spring-cage terminal block |
 |
2700572 |
Phoenix Contact |
|
PSR-MC60-2NO-1DO-24DC-SP: Safety relay for two-hand control devices according to EN 574 type IIIA up to SILCL 1 Cat. 1 PL c synchronous activation monitoring < 0.5 s 2 enabling current paths U = 24 V DC plug-in spring-cage terminal block |
 |
2700574 |
Phoenix Contact |
|
PSR-MC62-2NO-1DO-24DC-SC: Safety relay for two-hand control devices according to EN 574 type IIIC up to SILCL 3 Cat. 4 PL e synchronous activation monitoring < 0.5 s 2 enabling current paths U = 24 V DC plug-in screw terminal block |
 |
2700575 |
Phoenix Contact |
|
PSR-MC62-2NO-1DO-24DC-SP: Safety relay for two-hand control devices according to EN 574 type IIIC up to SILCL 3 Cat. 4 PL e synchronous activation monitoring < 0.5 s 2 enabling current paths U = 24 V DC plug-in spring-cage terminal block |
 |
2702094 |
Phoenix Contact |
|
PSR-MC70-2NO-1DO-24DC-SC: Safety relay for emergency stop safety doors light grid up to SILCL 1 Cat. 1 PL c 1- or 2-channel operation cross-circuit detection can be retriggered off delay/on delay 0.2 s to 60 s 2 enabling current paths U = 24 V DC plug-in s |
 |
2702095 |
Phoenix Contact |
|
PSR-MC70-2NO-1DO-24DC-SP: Safety relay for emergency stop safety doors light grid up to SILCL 1 Cat. 1 PL c 1- or 2-channel operation cross-circuit detection can be retriggered off delay/on delay 0.2 s to 60 s 2 enabling current paths U = 24 V DC plug-in s |
 |
2702096 |
Phoenix Contact |
|
PSR-MC72-2NO-1DO-24DC-SC: Safety relay for emergency stop safety doors light grid up to SILCL 3 Cat. 4 PL e 1- or 2-channel operation cross-circuit detection can be retriggered fall back/tightening delay 0.2 s to 60 s 2 enabling current paths U = 24 V DC p |
 |
2702097 |
Phoenix Contact |
|
PSR-MC72-2NO-1DO-24DC-SP: Safety relay for emergency stop safety doors light grid up to SILCL 3 Cat. 4 PL e 1- or 2-channel operation cross-circuit detection can be retriggered fall back/tightening delay 0.2 s to 60 s 2 enabling current paths U = 24 V DC p |
 |
2702411 |
Phoenix Contact |
|
PSR-MC37-3NO-1NC-24DC-SC: Safety relay for emergency switching off and safety doors as well as for elevator applications up to SILCL 3 Cat. 4 PL e 1 or 2-channel operation automatic or manual start cross-circuit detection 3 enabling current paths U = 24 V |
 |
2702412 |
Phoenix Contact |
|
PSR-MC37-3NO-1NC-24DC-SP: Safety relay for emergency switching off and safety doors as well as for elevator applications up to SILCL 3 Cat. 4 PL e 1 or 2-channel operation automatic or manual start cross-circuit detection 3 enabling current paths U = 24 V |