IB IL 24 LPSDO 8 V2-PAC Safety-related digital output module IP20 protection for the SafetyBridge system. The module has four safe digital outputs with two-channel occupancy or 8 safe digital outputs with single-channel occupancy 2700606 Phoenix Contact
IB IL 24 LPSDO 8 V2-PAC Safety-related digital output module IP20 protection for the SafetyBridge system. The module has four safe digital outputs with two-channel occupancy or 8 safe digital outputs with single-channel occupancy
IB IL 24 PSDI 16-PAC Safety-related digital input module IP20 protection for the SafetyBridge INTERBUS-Safety and PROFIsafe system. The module has 8 safe digital inputs for two-channel assignment or 16 safe digital inputs for single-channel assignment. 2700994 Phoenix Contact
IB IL 24 PSDI 16-PAC Safety-related digital input module IP20 protection for the SafetyBridge INTERBUS-Safety and PROFIsafe system. The module has 8 safe digital inputs for two-channel assignment or 16 safe digital inputs for single-channel assignment.
IB IL 24 LPSDO 8 V3-PAC Safety-related digital output module IP20 protection for the SafetyBridge system. The module has four safe digital outputs with two-channel occupancy or 8 safe digital outputs with single-channel occupancy 2701625 Phoenix Contact
IB IL 24 LPSDO 8 V3-PAC Safety-related digital output module IP20 protection for the SafetyBridge system. The module has four safe digital outputs with two-channel occupancy or 8 safe digital outputs with single-channel occupancy
PI-EX-NAM/RNO-NE Ex-i binary input: NAMUR isolation amplifiers. For operating proximity sensors and switches in Ex areas. The binary signals are transmitted to a safe area. Relay output (N/O contact) line fault detection. Galvanic 3-way isolation. 2835341 Phoenix Contact
PI-EX-NAM/RNO-NE Ex-i binary input: NAMUR isolation amplifiers. For operating proximity sensors and switches in Ex areas. The binary signals are transmitted to a safe area. Relay output (N/O contact) line fault detection. Galvanic 3-way isolation.
PI-EX-TB Ex base terminal block for intrinsically safe signals with knife disconnection and test connections 2835901 Phoenix Contact
PI-EX-TB Ex base terminal block for intrinsically safe signals with knife disconnection and test connections
MACX MCR-EX-SL-RPSSI-I Ex-i repeater power supply and input signal conditioner HART. Sends fed or active 0/4-20 mA signals from the Ex area to a load (active or passive) to the safe area. Electrical 3-way isolation SIL 2 in accordance with IEC 61508. 2865340 Phoenix Contact
MACX MCR-EX-SL-RPSSI-I Ex-i repeater power supply and input signal conditioner HART. Sends fed or active 0/4-20 mA signals from the Ex area to a load (active or passive) to the safe area. Electrical 3-way isolation SIL 2 in accordance with IEC 61508.
MACX MCR-EX-SL-RPSSI-2I Measuring transducer power supply and input isolating amplifier HART-transparent. Transfers supplied or active 0/4-20 mA signals from the Ex area galv. isolated to two loads in the safe area. Galvanic 4-way isolation SIL 2 according 2865366 Phoenix Contact
MACX MCR-EX-SL-RPSSI-2I Measuring transducer power supply and input isolating amplifier HART-transparent. Transfers supplied or active 0/4-20 mA signals from the Ex area galv. isolated to two loads in the safe area. Galvanic 4-way isolation SIL 2 according
MACX MCR-EX-SL-IDSI-I Ex-i output signal conditioner HART Isolates and sends intrinsically safe 0/4-20 mA signals to a load (I/P converters control valves displays) in Ex areas. Electrical 3-way isolation wire break recognition SIL 2 in accordance with IEC 2865405 Phoenix Contact
MACX MCR-EX-SL-IDSI-I Ex-i output signal conditioner HART Isolates and sends intrinsically safe 0/4-20 mA signals to a load (I/P converters control valves displays) in Ex areas. Electrical 3-way isolation wire break recognition SIL 2 in accordance with IEC
MACX MCR-EX-SL-NAM-R Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via a relay output (PDT contact) to the safe area. Line fault detection (LFD) 3-way isolation SIL 2. 2865434 Phoenix Contact
MACX MCR-EX-SL-NAM-R Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via a relay output (PDT contact) to the safe area. Line fault detection (LFD) 3-way isolation SIL 2.
MACX MCR-EX-SL-NAM-2RO Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD) 3-way isolation SIL 2. 2865450 Phoenix Contact
MACX MCR-EX-SL-NAM-2RO Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 relay outputs (N/O contact) to the safe area. Line fault detection (LFD) 3-way isolation SIL 2.